1) Gepstein L, Hayam G, Ben-Heim SA. A novel method for nonfluoroscopic catheter-based elec-troanatomical mapping of the heart. Circulation. 1997; 95: 1611-22
|
|
|
2) Schilling RJ, Peters NS, Davies DW. Feasibility of a non-contact catheter for endocardial mapping of human ventricular tachycardia. Circulation. 1999; 99: 2543-52
|
|
|
3) Sra J, Hauck J, Krum D, et al. Three-dimensional right atrial geometry construction and catheter tracking using cutaneous patches. J Cardiovasc Electrophysiol. 2003; 14: 897
|
|
|
4) Dong J, Calkins H, Solomon SB, et al. Integarated electroanatomical mapping with three-diemasio-nal computed tomographic images for real-time guided ablations. Circulation. 2006; 113: 186-94
|
|
|
5) Dong J, Dickfeld T, Dalal D, et al. Initial experience in the use of integrated electro-anatomic mapping with three-dimensional MR/CT images to guide catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol. 2006; 17: 459-66
|
|
|
6) Haïssaguerre M, et al. Fusion of multislice computed tomography imaging with three-dimensional electroanatomic mapping to guide radiofrequency catheter ablation procedure. Heart Rhythm. 2005; 2: 1076-81
|
|
|
7) Knecht S, et al. Multidetector 16-slice CT scan evaluation of cavotricuspid isthmus anatomy before radiofrequency ablation. J Interv Card Electrophysiol. 2007; 20: 29-35
|
|
|
8) Mykytsey A, Kehoe R, Bharati S, et al. Right coronary artery occlusion during RF ablation of typical atrial flutter. J Cardiovasc Electrophysiol. 2010; 7: 818-21
|
|
|
9) Sciarra L, Dottori S, De Ruvo E, et al. The new electroanatomical Carto3 mapping system: three-dimensional right ventricular fast anatomical map resolution in comparison to magnetic resonance image. J Cardiovasc Med. 2011; 6: 434-5
|
|
|
10) Khaykin Y, Skanes A, Whaley B, et al. Real-time integration of 2D intracardiac echocardiography and 3D electroanatomical mapping to guide ventricular tachycardia ablation. Heart Rhythm. 2008; 10: 1396-402
|
|
|
11) Friedman PA, Asirvatham SJ, Grice S, et al. Noncontact mapping to guide ablation of right ventricular outflow tract tachycardia. J Am Coll Cardiol. 2002; 11: 1808-12
|
|
|
12) Casella M, Pelargonio G, Dello Russo A, et al. “Near-zero" fluoroscopic exposure in supraven-tricular arrhythmia ablation using the EnSite NavXTM mapping system: personal experience and review of the literature. J Interv Card Electrophysiol. 2011; 31: 109-18
|
|
|
13) Oral H, Knight BP, Ozaydin M, et al. Segmental ostial ablation to isolate the pulmonary veins during atrial fibrillation: feasibility and me-chanistic insights. Circulation. 2002; 10: 1256-62
|
|
|
14) OʼNeill MD, Jais P, Takahashi Y, et al. The stepwise ablation approach for chronic atrial fibrillation-evidence for a cumulative effect. J Interv Card Electrophysiol. 2006; 3: 153-67
|
|
|
15) Kumagai K, Muraoka S, Mitsutake C, et al. A new approach for complete isolation of the posterior left atrium including pulmonary veins for atrial fibrillation. J Cardiovasc Electrophysiol. 2007; 10: 1047-52
|
|
|
16) Nademanee K, McKenzie J, Kosar E, et al. A new approach for catheter ablation of atrial fibril-lation: mapping of the electrophysiologic subs-trate. J Am Coll Cardiol. 2004; 11: 2044-53
|
|
|
17) Scherlag BJ, Nakagawa H, Jackman WM, et al. Electrical stimulation to identify neural elements on the heart: their role in atrial fibrillation. J Interv Card Electrophysiol. 2005; 13 Suppl 1: 37-42
|
|
|
18) Miyake CY, Mah DY, Atallah J, et al. Non-fluoroscopic imaging systems reduce radiation exposure in children undergoing ablation of supraventricular tachycardia. Heart Rhythm. 2011; 4: 519-25
|
|
|
19) Wu J, Estner H, Luik A, et al. Automatic 3D mapping of complex fractionated atrial electro-grams (CFAE) in patients with paroxysmal and persistent atrial fibrillation. J Cardiovasc Electrophysiol. 2008; 9: 897-903
|
|
|
20) Calò L, De Ruvo E, Sciarra L, et al. Diagnostic accuracy of a new software for complex frac-tionated electrograms identification in patients with persistent and permanent atrial fibrillation. J Cardiovasc Electrophysiol. 2008; 10: 1024-30
|
|
|
21) Verma A, Wulffhart Z, Beardsall M, et al. Spatial and temporal stability of complex fractionated electrograms in patients with persistent atrial fibrillation over longer time periods: relationship to local electrogram cycle length. Heart Rhythm. 2008; 8: 1127-33
|
|
|
22) Aizer A, Holmes DS, Garlitski AC, et al. Standardization and validation of an automated algorithm to identify fractionation as a guide for atrial fibrillation ablation. Heart Rhythm. 2008; 8: 1134-41
|
|
|
23) Lin YJ, Tsao HM, Chang SL, et al. Role of high dominant frequency sites in nonparoxysmal atrial fibrillation patients: insights from high-density frequency and fractionation mapping. Heart Rhythm. 2010; 9: 1255-62
|
|
|
24) Cappato R, Calkins H, Chen SA, et al. Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circulation. 2005; 111: 1100-5
|
|
|
25) Pappone C, Oral H, Santinelli V, et al. Atrio-esophageal fistula as a complication of percu-taneous transcatheter ablation of atrial fibril-lation. Circulation. 2004; 109: 2724-6
|
|
|
26) Sacher F, Monahan KH, Thomas SP, et al. Phrenic nerve injury after atrial fibrillation catheter ablation: characterization and outcome in a multicenter study. J Am Coll Cardiol. 2006; 47: 2498-503
|
|
|
27) Shah D, Dumonceau JM, Burri H, et al. Acute pyloric spasm and gastric hypomotility: an extracardiac adverse effect of percutaneous radiofrequency ablation for atrial fibrillation. J Am Coll Cardiol. 2005; 46: 327-30
|
|
|